Polish dashboard UX and update README
- Wrap simulation controls in form to prevent page reruns on change - Fix TempCo test configs to use 2+ temperature points - Add Installation, Quick Start, and usage examples to README
This commit is contained in:
@@ -233,63 +233,72 @@ def display_controls() -> None:
|
||||
|
||||
st.sidebar.divider()
|
||||
|
||||
# Time multiplier
|
||||
st.sidebar.subheader("Simulation Speed")
|
||||
st.sidebar.select_slider(
|
||||
"Time Multiplier",
|
||||
options=[1, 2, 5, 10, 20, 50, 100],
|
||||
value=10,
|
||||
format_func=lambda x: f"{x}x",
|
||||
key="time_multiplier",
|
||||
)
|
||||
st.sidebar.caption(
|
||||
f"1 real second = {st.session_state.get('time_multiplier', 10)} simulation seconds"
|
||||
)
|
||||
# Parameter Controls - wrapped in form to prevent reruns on every change
|
||||
with st.sidebar.form("parameter_controls"):
|
||||
st.subheader("Simulation Parameters")
|
||||
st.caption("💡 Change parameters below, then click Apply to update the simulation")
|
||||
|
||||
st.sidebar.divider()
|
||||
# Time multiplier
|
||||
time_multiplier = st.select_slider(
|
||||
"Time Multiplier",
|
||||
options=[1, 2, 5, 10, 20, 50, 100],
|
||||
value=st.session_state.get("time_multiplier", 10),
|
||||
format_func=lambda x: f"{x}x",
|
||||
)
|
||||
st.caption(f"1 real second = {time_multiplier} simulation seconds")
|
||||
|
||||
# Temperature setpoint
|
||||
st.sidebar.subheader("Thermal Chamber")
|
||||
st.sidebar.slider(
|
||||
"Temperature Setpoint (C)",
|
||||
min_value=-40.0,
|
||||
max_value=125.0,
|
||||
value=25.0,
|
||||
step=5.0,
|
||||
key="temp_setpoint",
|
||||
)
|
||||
st.divider()
|
||||
|
||||
st.sidebar.divider()
|
||||
# Temperature setpoint
|
||||
st.markdown("**Thermal Chamber**")
|
||||
temp_setpoint = st.slider(
|
||||
"Temperature Setpoint (C)",
|
||||
min_value=-40.0,
|
||||
max_value=125.0,
|
||||
value=st.session_state.get("temp_setpoint", 25.0),
|
||||
step=5.0,
|
||||
)
|
||||
|
||||
# Power supply controls
|
||||
st.sidebar.subheader("Power Supply")
|
||||
st.sidebar.slider(
|
||||
"Input Voltage (V)",
|
||||
min_value=0.0,
|
||||
max_value=12.0,
|
||||
value=5.0,
|
||||
step=0.1,
|
||||
key="input_voltage",
|
||||
)
|
||||
st.divider()
|
||||
|
||||
st.sidebar.toggle(
|
||||
"Output Enabled",
|
||||
value=False,
|
||||
key="output_enabled",
|
||||
)
|
||||
# Power supply controls
|
||||
st.markdown("**Power Supply**")
|
||||
input_voltage = st.slider(
|
||||
"Input Voltage (V)",
|
||||
min_value=0.0,
|
||||
max_value=12.0,
|
||||
value=st.session_state.get("input_voltage", 5.0),
|
||||
step=0.1,
|
||||
)
|
||||
|
||||
st.sidebar.divider()
|
||||
output_enabled = st.toggle(
|
||||
"Output Enabled",
|
||||
value=st.session_state.get("output_enabled", False),
|
||||
)
|
||||
|
||||
# Load controls
|
||||
st.sidebar.subheader("Electronic Load")
|
||||
st.sidebar.slider(
|
||||
"Load Current (mA)",
|
||||
min_value=0.0,
|
||||
max_value=500.0,
|
||||
value=100.0,
|
||||
step=10.0,
|
||||
key="load_current",
|
||||
)
|
||||
st.divider()
|
||||
|
||||
# Load controls
|
||||
st.markdown("**Electronic Load**")
|
||||
load_current = st.slider(
|
||||
"Load Current (mA)",
|
||||
min_value=0.0,
|
||||
max_value=500.0,
|
||||
value=st.session_state.get("load_current", 100.0),
|
||||
step=10.0,
|
||||
)
|
||||
|
||||
# Apply button
|
||||
submitted = st.form_submit_button("✅ Apply Changes", type="primary", use_container_width=True)
|
||||
|
||||
if submitted:
|
||||
# Update session state with new values
|
||||
st.session_state.time_multiplier = time_multiplier
|
||||
st.session_state.temp_setpoint = temp_setpoint
|
||||
st.session_state.input_voltage = input_voltage
|
||||
st.session_state.output_enabled = output_enabled
|
||||
st.session_state.load_current = load_current
|
||||
st.rerun()
|
||||
|
||||
|
||||
@st.fragment(run_every=0.1)
|
||||
@@ -613,13 +622,13 @@ def test_execution_page() -> None:
|
||||
runner: TestRunner = st.session_state.test_runner
|
||||
instruments: InstrumentSet = st.session_state.instruments
|
||||
|
||||
# Connect instruments before running test
|
||||
# Instruments should already be connected from dashboard startup
|
||||
# Just verify they're connected
|
||||
try:
|
||||
instruments.chamber.transport.connect() # type: ignore[attr-defined]
|
||||
instruments.psu.transport.connect() # type: ignore[attr-defined]
|
||||
instruments.dmm.transport.connect() # type: ignore[attr-defined]
|
||||
# Quick connectivity check
|
||||
_ = instruments.chamber.get_temperature()
|
||||
except Exception as e:
|
||||
st.error(f"Failed to connect to instruments: {e}")
|
||||
st.error(f"Instruments not available: {e}")
|
||||
st.session_state.test_running = False
|
||||
st.stop()
|
||||
|
||||
|
||||