- Wrap simulation controls in form to prevent page reruns on change
- Fix TempCo test configs to use 2+ temperature points
- Add Installation, Quick Start, and usage examples to README
Redesign integration test architecture to eliminate async/sync deadlock:
- Run SimulationServer in dedicated background thread with own event loop
- Rewrite TempCo tests as fully synchronous (no @pytest.mark.asyncio)
- Add ServerThread fixture in tests/integration/conftest.py
- Fix Unicode encoding errors (replace deg, mu, +/- with ASCII)
- Optimize temperature points for faster settling (23C, 25C, 27C)
All 3 TempCo integration tests now passing in ~5 minutes total.
- Revert server to only send responses for non-empty strings
Per SCPI protocol: successful commands with no output send nothing
- Add TEMP:RAMP command support to thermal chamber simulator
- Fixes test_multiple_commands and test_physics_engine_integration
TCP server integration tests now passing (8/8).
TempCo integration tests still need work due to async/sync mixing.
- Always send a response (even empty) to prevent client timeouts
- Add pandas-stubs to dev dependencies for mypy type checking
- Server now sends newline-terminated response for all commands
This fixes the mypy CI failure. Integration test failures still need
investigation - likely due to event loop blocking when mixing sync/async.
- Use X | None syntax instead of Optional[X] (UP045)
- Sort imports in dashboard app (I001)
- Remove unnecessary UTF-8 encoding argument (UP012)
- Add 'from err' to exception re-raises (B904)
- Remove unused imports in integration tests (F401)
- Fix useless expression in test (B018)
- Cast **1.5 result to float in LDO model (mypy no-any-return)
- Use functools.partial instead of lambda in server (mypy misc)
InstrumentServer is a general-purpose SCPI-over-TCP server that can
host any device implementing the SCPIDevice protocol (process method).
Moving it from simulation/ to instruments/transport/ reflects this:
- simulation package now depends on instruments package
- InstrumentServer can host both virtual and real instrument adapters
- Added SCPIDevice Protocol for type-safe device registration
Create SimulationServer that wires physics engine to all virtual
instruments and exposes them over TCP. Add 'serve' CLI command to
start the server with configurable ports and physics rate.
Create InstrumentServer class with asyncio for hosting virtual SCPI
instruments over TCP. Supports registering instruments on specific
ports with port-to-instrument mapping.
Implement SCPI-based virtual DMM with DC voltage and current measurement.
Supports MEAS, CONF, and READ commands. Integrates with physics engine
for DUT output measurements.
Implement SCPI-based virtual power supply with voltage/current control
and output enable commands. Integrates with physics engine for DUT
input voltage simulation.
- TEMP:SETPOINT: Set/query target temperature
- TEMP:ACTUAL?: Query actual chamber temperature from physics engine
- TEMP:STAB?: Query temperature stability (within 0.5°C threshold)
Provides SCPI command parsing and dispatch mechanism for virtual
instruments. Includes IEEE 488.2 common commands (*IDN?, *RST, *CLS,
*OPC) and abstract methods for instrument-specific implementations.