# py_dvt_ate Default Configuration # This file contains default settings for the DVT simulation platform. # Copy this file and modify values as needed for your environment. # ============================================================================= # Instrument Configuration # ============================================================================= instruments: # Backend selection: "simulator" or "pyvisa" # - simulator: Use virtual instruments with physics simulation (for development) # - pyvisa: Connect to real instruments via PyVISA (for production testing) backend: simulator # Simulator backend configuration # Used when backend=simulator. Virtual instruments are exposed as TCP servers. simulator: host: localhost thermal_chamber_port: 5001 power_supply_port: 5002 multimeter_port: 5003 # PyVISA backend configuration # Used when backend=pyvisa. Provide VISA resource strings for real instruments. # Example: "TCPIP::192.168.1.10::5001::SOCKET" pyvisa: thermal_chamber: null power_supply: null multimeter: null # ============================================================================= # Physics Simulation Parameters # ============================================================================= physics: # Physics engine update rate (Hz) # Higher rates provide better accuracy but use more CPU. update_rate_hz: 100.0 # Thermal model parameters thermal: # Chamber thermal time constant (seconds) # Time for chamber temperature to reach 63% of final value chamber_time_constant_s: 30.0 # DUT case thermal time constant (seconds) # Time for case temperature to reach 63% of final value case_time_constant_s: 5.0 # Junction-to-case thermal resistance (°C/W) # How much the junction heats above case per watt dissipated theta_jc: 15.0 # Case-to-ambient thermal resistance (°C/W) # How much the case heats above ambient per watt dissipated theta_ca: 5.0 # Thermal chamber behaviour chamber: # Maximum temperature ramp rate (°C/min) # Real chambers have limited heating/cooling rates ramp_rate_c_per_min: 10.0 # Temperature stability window (°C) # Chamber is considered stable when within ±this value of setpoint stability_window_c: 0.5 # Stability duration requirement (seconds) # Chamber must remain in stability window for this duration stability_time_s: 30.0 # ============================================================================= # DUT (Device Under Test) Configuration # ============================================================================= dut: # DUT model type # Currently supported: "ldo" model: ldo # DUT model parameters parameters: # Nominal output voltage at 25°C (V) nominal_output_voltage: 3.3 # Temperature coefficient (ppm/°C) # Voltage change per degree: ΔV = V₀ × tempco × ΔT / 1e6 tempco_ppm_per_c: 50.0 # Quiescent current at 25°C (µA) quiescent_current_ua: 50.0 # Quiescent current temperature coefficient (per °C) # Iq change per degree: ΔIq = Iq₀ × tempco × ΔT quiescent_current_tempco: 0.003 # Dropout voltage (V) # Minimum Vin-Vout differential for regulation dropout_voltage: 0.3 # ============================================================================= # Data Storage Configuration # ============================================================================= data: # SQLite database path for test runs and results database_path: ./data/py_dvt_ate.db # Directory for measurement data files (Parquet format) measurements_dir: ./data/measurements # Directory for generated reports (PDF, HTML) reports_dir: ./data/reports # ============================================================================= # Logging Configuration # ============================================================================= logging: # Logging level: DEBUG, INFO, WARNING, ERROR, CRITICAL level: INFO # Log file path # Use null to disable file logging file: ./data/logs/py_dvt_ate.log # Log message format # Uses Python logging format strings format: "%(asctime)s - %(name)s - %(levelname)s - %(message)s" # ============================================================================= # Dashboard Configuration (Streamlit) # ============================================================================= dashboard: # Enable/disable the Streamlit dashboard enabled: true # Dashboard server port port: 8501 # ============================================================================= # API Configuration (Phase 2) # ============================================================================= api: # Enable/disable the REST API server # Currently not implemented (Phase 2 feature) enabled: false # API server host # Use "0.0.0.0" to listen on all interfaces host: "0.0.0.0" # API server port port: 8000